m (Links)
(Intro)
Line 1: Line 1:
  +
In order to create the ideal environment for your cultivar, it is essential to be able to accurately measure temperature, humidity, pH, and light intensity. When providing additional Co<sub>2</sub>, a Co<sub>2</sub> sensor is also crucial. The sensors available to the consumer broadly fall into three categories: cheap and generic, DIY sensors for microcontrollers, and expensive "professional" devices. The cheap and generic devices can yield good results but aren't very accurate. Sensors to be used with microcontrollers are equally cheap but much more accurate with the caveat that they require a little electronics knowledge to use. Finally, "professional" devices are very accurate but much more expensive than other options. Generally speaking, the more accurate your sensors are the better growth (and yield) you will be able to achieve.
In order to create the ideal [[Growing environments|environment]] for your cultivar, it is essential to be able to accurately measure it.
 
   
 
== Humidity and Temperature ==
 
== Humidity and Temperature ==
There is a wide range of generic [[Temperature and Humidity|humidity and temperature]] sensors that are cheaply available. Some connect to a smartphone via Bluetooth and provide a graph of data while others incorporate a small LCD to display current readings.
+
There is a wide range of generic [[Temperature and Humidity|humidity and temperature]] sensors that are cheaply available and provide reasonable accuracy. They generally incorporate a small LCD to display current readings and are widely used during curing as they fit inside most mason jars.
 
<div align='center'><ul>
 
 
<li style="display: inline-block;"> [[File:Square sensor.png|thumb|none|217x217px]] </li>
<div align='center'>
 
 
<li style="display: inline-block;"> [[File:Round humidity sensor.png|thumb|none|225x225px]] </li>
<ul>
 
<li style="display: inline-block;"> [[File:Square sensor.png|thumb|none|300px]] </li>
 
<li style="display: inline-block;"> [[File:Round humidity sensor.png|thumb|none|300px]] </li>
 
 
</ul>
 
</ul>
 
</div>
 
</div>
  +
<p align='center'>Some generic examples</p>More accurate DIY sensors include the BME280 or BME680. DHT11 and DHT22 are often used to measure temp and humidity but the accuracy of humidity measurements in these sensors is too low to be useful for cultivation.
<p align='center'>Some generic examples</p>
 
   
 
== Light ==
 
== Light ==
Line 16: Line 14:
   
 
== pH ==
 
== pH ==
When mixing concentrated liquid nutrients with water it's important to ensure the nutrient mix has the correct pH before applying to the cultivar so that it can make use of the nutrients. There is no shortage of digital meters to choose from, however, many cheap digital meters are inaccurate and may drift over time. A digital meter should be recalibrated every few months using a buffer solution depending on how heavy use is. The [[Growing_mediums|grow medium]] being used will determine the margin for error for the applied pH in regards to preventing [[Nutrients#Nutrient_lockout|nutrient lockout.]]
+
When mixing concentrated liquid nutrients with water it's important to ensure the nutrient mix has the correct pH before applying it to the cultivar so that it can make use of the nutrients (see: nutrient lockout). There is no shortage of generic digital meters to choose from, however, many cheap digital meters are inaccurate and more prone to drift over time. A digital meter should be recalibrated every few months using a buffer solution depending on how heavy the use is. The [[Growing_mediums|grow medium]] being used will determine the margin for error for the applied pH in regards to preventing [[Nutrients#Nutrient_lockout|nutrient lockout.]]
   
 
== Total dissolved solids (TDS) ==
 
== Total dissolved solids (TDS) ==

Revision as of 13:44, 29 March 2022

In order to create the ideal environment for your cultivar, it is essential to be able to accurately measure temperature, humidity, pH, and light intensity. When providing additional Co2, a Co2 sensor is also crucial. The sensors available to the consumer broadly fall into three categories: cheap and generic, DIY sensors for microcontrollers, and expensive "professional" devices. The cheap and generic devices can yield good results but aren't very accurate. Sensors to be used with microcontrollers are equally cheap but much more accurate with the caveat that they require a little electronics knowledge to use. Finally, "professional" devices are very accurate but much more expensive than other options. Generally speaking, the more accurate your sensors are the better growth (and yield) you will be able to achieve.

Humidity and Temperature

There is a wide range of generic humidity and temperature sensors that are cheaply available and provide reasonable accuracy. They generally incorporate a small LCD to display current readings and are widely used during curing as they fit inside most mason jars.

Some generic examples

More accurate DIY sensors include the BME280 or BME680. DHT11 and DHT22 are often used to measure temp and humidity but the accuracy of humidity measurements in these sensors is too low to be useful for cultivation.

Light

See Measuring light intensity

pH

When mixing concentrated liquid nutrients with water it's important to ensure the nutrient mix has the correct pH before applying it to the cultivar so that it can make use of the nutrients (see: nutrient lockout). There is no shortage of generic digital meters to choose from, however, many cheap digital meters are inaccurate and more prone to drift over time. A digital meter should be recalibrated every few months using a buffer solution depending on how heavy the use is. The grow medium being used will determine the margin for error for the applied pH in regards to preventing nutrient lockout.

Total dissolved solids (TDS)

A digital TDS meter can tell you how many dissolved solids such as minerals or nutrients are in your water. This can help make sure the right amount of nutrients are provided to the plant